Cryogenic operation of a SiGe integrated circuit for control time domain SQUID multiplexing
D. Prêle, F. Voisin, E. Bréelle and M. Piat AstroParticule et Cosmologie (APC), CNRS/UMR 7164, Univ. Paris 7, Denis Diderot, France;
damien.prele@apc.univ-paris7.frPublished online: 11 June 2009
Abstract
This paper presents an ultra low noise instrumentation based on cryogenic electronic integrated circuit. We have designed an ASIC (Application Specific Integrated Circuit) in standard BiCMOS SiGe 0.35
m AMS technology. The main functions of this circuit, the readout and the control of a 24 to 1 SQUID multiplexer, is presented. We also report the cryogenic operation of each part of this ASIC.
© EAS, EDP Sciences 2009
The OpenURL standard is a protocol for transmission of metadata describing the resource that you wish to access. An OpenURL link containsarticle metadata and directs it to the OpenURL server of your choice. The OpenURL server can provide access to the resource and also offer complementary services (specific search engine, export of references...). The OpenURL link can be generated by different means:
- if your librarian has set up your subscription with an OpenURL resolver, OpenURL links appear automatically on the abstract pages,
- you can define your own OpenURL resolver with your EDPS Account. In this case your choice will be given priority over that of your library,
- you can use an add-on for your browser (Firefox or I.E.) to display OpenURL links on a page (see http://www.openly.com/openurlref/). You should disable this module if you wish to use the OpenURL server that you or your library have defined.